LG Refrigerators

Error Code E Sd

Sub PCB communication error — communication error between main MICOM and Sub MICOM

Moderate

Address soon - your appliance may not work properly

Also displayed as: E Sd

How to Fix

  1. 1

    Step 1: Check all wiring harness connections between Main PCB and Sub PCB (door harness). Reseat any loose connectors.

  2. 2

    Step 2: Measure voltage at Sub CON1 8th Pin ~ 33rd Pin; must NOT be 0V or 5V. If stuck at 0V or 5V, check connection then replace Sub PCB.

  3. 3

    Step 3: Measure voltage at Sub CON1 10th Pin ~ 33rd Pin; must NOT be 0V or 5V. If stuck, check connection then replace Sub PCB.

  4. 4

    Step 4: Measure voltage at Main CON3 1st Pin ~ 15th Pin; must NOT be 0V or 5V. If stuck, check hinge connector then replace Display PCB.

  5. 5

    Step 5: Measure voltage at Main CON3 3rd Pin ~ 15th Pin; must NOT be 0V or 5V. If stuck, replace Display PCB.

  6. 6

    Step 6: If all voltages normal, explain to customer.